Stair stringer calculator

Find equal risers, tread count, horizontal run, and a stringer planning length for a straight stair flight.

Measurements and materials

Finished stair dimensions

Check your local building code before building.

Results

Select Calculate to see results for your measurements.

Use your results

How it works

How to measure

Measure plumb from the lower finished landing to the upper finished walking surface, including planned finish thickness. Enter the maximum riser height required for your project and the horizontal going between successive nosings. The upper landing serves as the final walking surface.

Formula

Round total rise ÷ maximum riser height up for the number of risers. Divide total rise by the riser count for equal height. There is one fewer separate tread than risers. Multiply treads by the going for total run and use √(rise² + run²) for the overall planning diagonal.

Worked example

Use a 2.7 m total finished rise, 180 mm maximum riser and 250 mm going.

There are 15 risers of exactly 180 mm and 14 separate treads. Total run is 3.50 m and the planning diagonal is √19.54 ≈ 4.42 m.

What changes the result

A rise just over a multiple of the maximum riser adds a step, which increases run and reduces each riser height. Changes to finished floor thickness can alter the first or last riser on site.

Assumptions and sources

Starter dimensions are editable calculation examples. Enter project requirements after checking your local building code.

Check your local building code before building. This straight-flight diagram and overall diagonal are for planning only. Stringer stock and cut geometry require allowances for attachments, end cuts, tread thickness and the support details.

Use this estimate for planning. For engineering or code-compliance questions, consult a qualified professional.

Method version 1.0