Rainwater harvesting calculator
Estimate how much roof runoff you can collect and the usable storage needed for a selected rainfall event.
Results
Select Calculate to see results for your measurements.
Use your results
How it works
How to measure
Measure the horizontal footprint of roof draining into the connected gutters. Use eave-to-eave plan dimensions instead of measuring along the slope. Add only sections that drain to the tank and enter local rainfall totals for your chosen event, month and year.
Formula
Multiply catchment area × rainfall depth × runoff coefficient for each period. One millimetre on one square metre is one litre before losses. The tank suggestion is the recoverable volume from one selected event, assuming it starts empty.
Worked example
A 100 m² connected roof, 25 mm event, 80 mm month, 900 mm year and 0.8 runoff coefficient.
Collect about 2,000 L per event, 6,400 L per month and 72,000 L per year. Start with 2,000 L of usable capacity to hold that single event from empty.
What changes the result
Larger connected areas or wetter periods yield more water. Rough or porous roofs can lose more rainfall than smooth roofs. Changing the selected event changes the single-event tank target.
Assumptions and sources
Rainfall values are worked examples. USDA NRCS groups metal, gravel and asphalt-shingle roofs at 0.75–0.95. UNEP’s Pacific Islands guide gives material-specific estimates of 0.62–0.69 for cement tile and 0.30–0.39 for machine-made clay tile. These reference ranges come from different conditions. Use measured runoff when available.
The estimate omits separate first-flush losses, demand between storms, overflow and unusable tank volume. Use local demand and daily rainfall for seasonal storage sizing. This tool estimates quantity only and does not evaluate water quality.
Use this estimate for planning. For engineering or code-compliance questions, consult a qualified professional.
- USDA NRCS Engineering Field Handbook, urban agriculture, figure 650T-42 (checked )
- UNEP Harvesting the Heavens, table 3.4 of roof runoff coefficients (checked )
- Washington State Ecology rainwater harvesting and tank sizing guidance (checked )
- NIST SI conversion factors (checked )
Method version 1.0